Customization: | Available |
---|---|
Frequency Range: | 5150-5350MHz |
Frequency: | 5150-5350MHz |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
frequency range (MHz) | Power (W) | Current | Signal Source |
433-434 | 100w | <6.5A | DDS |
860-925 | 100w | <7A | DDS |
1160-1280 | 100w | <7.5A | DDS |
1560-1620 | 100w | <7.5A | DDS |
2400-2500 | 100w | < 10 A | DDS |
5150-5350 | 100w | < 9 A | DDS |
5700-5900 | 100w | < 9 A | DDS |
Test Item | Parameter | Remarks | ||
Working Voltage | 28V | 24-36V | ||
Output Power Is Adjustable | 50W~100W | Set the power of the software | ||
ALC Power Adjustment Range | ≤ 5 dB | Pressure control attenuation | ||
In-Band Fluctuations | ± 1 .5dB | peak-to-peak value | ||
stray launch | Work Belt In | ≤-15dBm/1MHz | Measure the maximum output | |
work out-off-band |
9KHz~1GHz | There is no higher than normal background noise |
power of the center frequency plus CW signal |
|
1G~12.75GHz | ||||
Output voltage standing wave ratio | ≤1.5 0 | Power on, double directional coupler test |
||
High and low temperature test |
working temperature (ºC) |
- 25~+ 85ºC | Low temperature start, monitoring work is normal |
|
Power stability | ±1 .5dB @- 25ºC~+85ºC | |||
Power supply interface, communication interface RS485 |
7W2 public head | A1: 28V,A2: GND;1:485A, 2:485B |
||
RF output connector | N-F connect | |||
LCD liquid crystal display | Display frequency, power, switch status | |||
It has 3 LED lights | POWER: power indicator; RUN: run indicator; ALARM: alarm indicator; |
|||
Appearance dimensions | 15 7*12 3* 28 mm | |||
weight | 0.8 Kg | |||
Appearance (usage) | The aluminum cavity needs to be cooled by adding heat dissipation teeth |
Monitoring Function | Description | Remarks | |
Set parameters for the power amplifier section |
Power amplifiers witch | Turn on or off the amplifier | |
Alarm switch | Turn on or off the alarm function | ||
Downstream power control | The maximum output power of the amplifier can be set, and the adjustment range is greater than 20dB. High, medium and low power levels can be set | ||
High temperature alarm and protection |
When the temperature exceeds 85ºC, it will be automatically closed; when the temperature drops to 65ºC, it will be automatically restored | ||
The standing wave ratio alarm is on |
When the standing wave ratio is greater than 4, it is automatically closed | ||
Over current alarm | When the current exceeds 12A, it will be automatically closed | ||
Power deficit alarm | When the power is less than 37dBm, a low power alarm is displayed | ||
Over voltage alarm | It automatically shuts down when the voltage exceeds 32V | ||
Check the parameters of the power amplifier |
Power amplifier switch status | If the power amplifier is set to "OFF", it is in the closed state; otherwise, it is in the running state | |
Downstream output power level value |
Measure the output power value of the amplifier, detection range (Pomax+2, Pomax-20) | Detection accuracy: Pout±1dB |
|
Downward standing wave ratio |
The normal value of the received standing wave is 1.2, and the query value is 4.0 when the load is mismatched | ||
Temperature query |
Check the internal temperature of the module, detection range: -40ºC~+100ºC | Detection error: ±3ºC | |
ALC value query |
The displayed value is equal to the actual ALC value | ||
Voltage detection |
Check the operating voltage of the module | ||
Current detection |
Measure the operating current of the module | ||
Signal source Settings |
Frequency setting mode 1 | Any single frequency point can be set within the range | The frequency setting accuracy is 1M, the maximum bandwidth is 450MHz, and the maximum bandwidth is 6G |
Frequency setting mode 2 | Set the parameters such as broadband sweep mode, frequency, interval and step | ||
Frequency setting mode 3 | Set any 4 sub-frequency bands within the bandwidth, and each sub-frequency band should be incremental | ||
Module communication | RS485 | ||
Interface definition | A1: 28V,A2: GND; 1:485A,2:485B |