POWER:Power Supply pilot lamp;
RUN:Run pilot lamp;
ALARM:Fault alarm pilot lamp.
Monitoring type
RS485,Baud rate 19200
Monitoring function
1. Power amplifier query:module status (including power amplifier status, over temperature alarm, standing wave ratio alarm, power
amplifier fault alarm);
2. Power amplifier enable switch: Turn on or off the power amplifier.
3. Over temperature alarm: The temperature threshold is +85ºC. If the detected temperature exceeds +85ºC, an alarm will be
triggered, and the power amplifier will be turned off. When it reaches +65ºC, the power amplifier will be turned on;
4. Power amplifier standing wave alarm:When the power amplifier standing wave detection is greater than 4.0, the power amplifier
starts protection;
5. Overvoltage alarm of power amplifier:When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut
down;
6. Power amplifier undervoltage alarm: When the power amplifier voltage is below 24V, the power amplifier will automatically shut
down