Customization: | Available |
---|---|
Frequency Range: | 860-1100MHz |
Frequency: | 860-1100MHz |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Indicator requirements | remarks |
Frequency (Mhz) | 860~1100MHz | |
Signal Bandwidth | 250MHz | VCO |
Saturated Output Power | 50±1dB | |
Large Signal Gain | 50±1dB | |
Gain Flatness | ≤4.0dB | |
Gain Stability | ± 1.5dB | at -25ºC~+55ºC |
Power stability | ± 1.5dB | at -25ºC~+55ºC |
DC Input Voltage | DC28±1.0V | |
Current Consumption | 10.5Atyp; 12.5A max. |
@ Pout=20W CW, 50 ohms load |
Monitoring interface | PHD2.0MM-2*3PIN Socket, PIN1: RS485A; PIN2: RS485B; PIN3: GND; PIN4,PIN5,PIN6: NC; PIN6: Power amplifier enable switch,High level +5V off, low level 0V on. |
|
Monitoring type | RS485,Baud rate 19200 | |
Monitoring function | 1. Power amplifier query:module status (including power amplifier status, over temperature alarm, standing wave ratio alarm, power amplifier fault alarm); 2. Power amplifier enable switch: Turn on or off the power amplifier. 3. Over temperature alarm: The temperature threshold is +85ºC. If the detected temperature exceeds +85ºC, an alarm will be triggered, and the power amplifier will be turned off. When it reaches +65ºC, the power amplifier will be turned on; 4. Power amplifier standing wave alarm:When the power amplifier standing wave detection is greater than 4.0, the power amplifier starts protection; 5. Overvoltage alarm of power amplifier:When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down; 6. Power amplifier undervoltage alarm: When the power amplifier voltage is below 24V, the power amplifier will automatically shut down |
|
RF output connector | SMA-KFD | |
Dimension | 150×79.5×20mm | |
Installation Dimension | 144×73.5×20mm | |
Screw Size | 4-Ø3.2mm |